Product specifications
Seismic isolation table dimensions and specifications
|
Easy installation type | |
---|---|---|
Model | TSD-450 | TSD-400 |
Body dimensions | ||
450 (W) × 450 (D) × 80 (H) | 400 (W) × 1000 (D) × 90 (H) | |
Seismic isolation capability | Response acceleration of 0.2 G or less for input acceleration of 0.8 G (TSD-450: Response acceleration of 0.2 G or less for input acceleration of 0.5 G) | |
Maximum deflection | ±200 mm (X direction, Y direction) (TSD-450: ±150 mm) | |
Load | 30 kg to 100 kg | 50 kg to 150 kg |
Seismic isolation direction | Horizontal direction | |
Table mass | 20 kg | 45 kg |
|
Linking type | |
---|---|---|
Model | TSD-1000 | TSD-1200 |
Body dimensions | ||
1000 (W) × 1000 (D) × 90 (H) | 1200 (W) × 1190 (D) × 90 (H) | |
Seismic isolation capability | Response acceleration of 0.2 G or less for input acceleration of 0.8 G | |
Maximum deflection | ±200 mm (X direction, Y direction) (TSD-450: ±150 mm) | |
Load | 300 kg to 1200 kg* | |
Seismic isolation direction | Horizontal direction | |
Table mass | 90kg | 110kg |
*Contact us for loads exceeding 800 kg.
Standard supplied parts
- Instruction manual
- Rubber sheet
- Area tape
- Wire (with sleeve)
- Wire fixing bolts, washers
- Cable support (with set screw)
- Hexagonal wrench
Note: Only items 1 and 3 are supplied with model TSD-450, and only items 1 to 5 are supplied with model TSD-400.